¡á »çÇÁÆ® ¸®Æ¬1Â÷¹èÅ͸® °íÃâ·Â ÆÄ¿ö¿ë LSH20 (Size D 3.6V 13000mAh) 2°³¸¦
º´·Ä·Î Á¶¸³ÇÏ¿© ¿ë·®À» ³ôÀÌ°í Ãâ·Â Àü¼±À» ¿¬°áÇÏ¿´½À´Ï´Ù.
¤Ñ ¼öÃàÇʸ§À¸·Î Æ÷ÀåÀÛ¾÷À» ÇÏ¿© ¹ß¼ÛÇØ µå¸³´Ï´Ù.
¤Ñ ±Ø¼ºÁÖÀÇ : Àü¼±ÀÇ »¡°£»öÀº Ç÷¯½º(+), °ËÀº»öÀº ¸¶À̳ʽº(-)
¡Þ Nominal voltage : 3.6V
¡Þ Nominal capacity : 26Ah (26,000mAh)
¡Þ Size : (D x2EA) 67 x 63 x 33.5mm (about)
¡Þ Weight : 202g (about)
¡Þ Pulse capability : Typically up to 8000mA (8A)
¡Þ Maximum recommended Continuous Current : 3600mA (3.6A)
¡Þ Operating temperature range : -60 ~+85 ¡É
¡Þ Storage (recommended) : + 30 ¡É Max.
¡Û ´Ù¸¥ ÇüÅÂÀÇ ÀÛ¾÷ÀÌ ÇÊ¿äÇϽøé ÀüÈ·Î ¸»¾¸ÇØÁÖ¼¼¿ä.
¤± (Á¶¸³)ÁýÇÕ¹èÅ͸®´Â ÁÖ¹®Á¦ÀÛÀ¸·Î ¹ÝÇ° ¹× ȯºÒÀÌ ¾È µÇ¿À´Ï ÁÖÀÇÇØÁÖ¼¼¿ä.
< ¡é ¾Æ·¡´Â ´Ü¼¿(1Cell)¿¡ ´ëÇÑ Á¤º¸ÀÔ´Ï´Ù >
1 Typical values relative to cells stored up to one year at + 30¡ÆC max.
2 Sleeved cell.
3 Dependent upon current drain, temperature, cut-off and cell orientation.
4 Under 4 A / 0.1 second pulses, drained every 2 minutes at + 20¡ÆC from undischarged cells
during 24 h, with 10 µA base current, yield voltage readings above 3.0 V after initial stabilisation.
The readings may vary according to the pulse characteristics, the temperature,
and the cell¡¯s previous history.
Fitting the cell with a capacitor may be recommended in severe conditions or for high pulse currents.
Consult Saft.
5 Operation above ambient temperature may lead to reduced capacity and lower voltage readings.
Consult Saft.
6 For more severe conditions, consult Saft.